INERT AIR SYSTEMS

NOTE: - 1/2" CABINET MOUNTING HARDWARE NOT SUPPLIED WITH UNIT. - NEMA 4X RATING PRIOR TO MODIFICATION FOR THE N2 SYSTEM COMPONENTS - CONVENIENCE PACKAGE INCLUDES CABINET LIGHT AND GFI OUTLET.

REGULATOR PANEL (CLICK HERE)

N2-0 - STANDARD PANEL ENCLOSURE - REGULATOR ENCLOSURE - 60" HIGH PRESSURE STAINLESS STEEL FLEX HOSE - 60W PTC HEATER INCLUDED - N2-OE-CONVENIENCE PACKAGE MODEL

- N2-1E-CONVENIENCE PACKAGE MODEL - 200W PTC HEATER INCLUDED STEEL FLEX HOSE - 48" HIGH PRESSURE STAINLESS - HOLDS 1 NITROGEN CYLINDER - SINGLE CYLINDER ENCLOSURE N2-1

INERT AIR SYSTEMS

NOTE: - 1/2" CABINET MOUNTING HARDWARE NOT SUPPLIED WITH UNIT. - NEMA 4X RATING PRIOR TO MODIFICATION FOR THE N2 SYSTEM COMPONENTS - CONVENIENCE PACKAGE INCLUDES CABINET LIGHT AND GFI OUTLET.

REGULATOR PANEL (CLICK HERE)

- N2-2E - CONVENIENCE PACKAGE MODEL - 200W PTC HEATER INCLUDED FLEX HOSE - 48" HIGH PRESSURE STAINLESS STEEL - HOLDS 2 NITROGEN CYLINDERS - DUAL CYLINDER ENCLOSURE N2-2

12.84

FLEX HOSE 60" SST BRASS TIP

BREATHER PLUG

.56 TYP

11.52

11.50

OUTLET

INLET

27.24

25.98

28.48

14.02

BREATHER PLUG

N2-0-SYSTEM

NOTES: 1. ALL CONTACTS IN THE DIAGRAM ARE SHOWN WITH THE SYSTEM DE-ENERGIZED AT ATMOSPHERIC PRESSURE. SW# 1 2. CONTACT RED-WHT : FACTORY SET TO CLOSE AT A PRESSURE OF 0.2 PSIG OR BELOW, SENDING AN ALARM, IF MONITORED. CONTACT BLK-WHT : FACTORY SET TO CLOSE AT A

NO LO C NO HI TRANS. TANK ALARMS

NITROGEN.STORAGE ALARM

TRANS TANK STORAGE TANK

HEATER SUPPLY POWER (VAC)

(4-20mA)

(4-20mA)

+ - + -

NO C NC

L1 N 120 N G

PRESSURE OF 5.5 PSIG OR ABOVE, SENDING AN ALARM, IF MONITORED. SW# 2

CONTACT BLU-BLK : N.C., OPENS AT 200.0 PSIG CONTACT RED-BLK : N.O., CLOSES AT 200.0 PSIG

DOOR GROUND STUD

CABINET GROUND STUD.

1 2

2 BLK BLK ALARM ENABLE SWITCH 2 1 1

WH

RED

BLK

RED

BLK

BLU

NC C NO 0.2 PSI 5.5 PSI

NC C NO

PS1

PG1

SW# 2

LOW PRESS

HIGH PRESS

BLIZZARD 60W PTC HEATER

SW# 1

RUST INHIBITOR CAPSULE

REGULATOR PANEL ASSEMBLY

WIRING DIAGRAM

BLIZZARD 60W PTC HEATER REGULATOR PANEL

FLEX HOSE 60", SST BRASS TIP

N2-0-SYSTEM

16.00 22.21

.56 TYP

13.21

OUTLET

INLET

65.18

61.25

14.32

N2-1-SYSTEM

NOTES: 1. ALL CONTACTS IN THE DIAGRAM ARE SHOWN WITH THE SYSTEM DE-ENERGIZED AT ATMOSPHERIC PRESSURE. SW# 1 2. CONTACT RED-WHT : FACTORY SET TO CLOSE AT A PRESSURE OF 0.2 PSIG OR BELOW, SENDING AN ALARM, IF MONITORED. CONTACT BLK-WHT : FACTORY SET TO CLOSE AT A

NO LO C NO HI TRANS. TANK ALARMS

TRANS TANK STORAGE TANK

SUPPLY POWER (VAC)

NITROGEN.STORAGE ALARM

HEATER

+ - (4-20mA)

+ - (4-20mA)

NO C NC

L1 N 120 N G

PRESSURE OF 5.5 PSIG OR ABOVE, SENDING AN ALARM, IF MONITORED. SW# 2

DOOR GROUND STUD

CABINET GROUND STUD.

CONTACT BLU-BLK : N.C., OPENS AT 200.0 PSIG CONTACT RED-BLK : N.O., CLOSES AT 200.0 PSIG

BLK BLK

RUST INHIBITOR CAPSULE

BLK PTC2

WHT

2

1

RED

BLK

BLU

NC C NO 0.2 PSI 5.5 PSI RED WH BLK

HEATER 200 W/ 120 VAC

NC C NO

PS1

1

2

SW# 2

PG1

LOW PRESS

HIGH PRESS

ALARM ENABLE SWITCH

SW# 1

WIRING DIAGRAM REGULATOR PANEL ASSEMBLY

REGULATOR PANEL

FLEX HOSE, 48" SST

HEATER 200 W/120 VAC

BREATHER FILTER

N2-1-SYSTEM

24.00 30.21

13.21

.56 TYP

77.16

73.25

74.50

15.32

N2-2-SYSTEM

NOTES: 1. ALL CONTACTS IN THE DIAGRAM ARE SHOWN WITH THE SYSTEM DE-ENERGIZED AT ATMOSPHERIC PRESSURE. SW# 1 2. CONTACT RED-WHT : FACTORY SET TO CLOSE AT A PRESSURE OF 0.2 PSIG OR BELOW, SENDING AN ALARM, IF MONITORED. CONTACT BLK-WHT : FACTORY SET TO CLOSE AT A

NO LO C NO HI TRANS. TANK ALARMS

TRANS TANK STORAGE TANK

NITROGEN.STORAGE ALARM

HEATER SUPPLY POWER (VAC)

(4-20mA)

(4-20mA)

+ - + -

NO C NC

L1 N 120 N G

PRESSURE OF 5.5 PSIG OR ABOVE, SENDING AN ALARM, IF MONITORED. SW# 2

CONTACT BLU-BLK : N.C., OPENS AT 200.0 PSIG CONTACT RED-BLK : N.O., CLOSES AT 200.0 PSIG

CABINET GROUND STUD

DOOR GROUND STUD

BLK PTC2

WHT

BLK BLK

2

1

NC C NO 0.2 PSI 5.5 PSI RED WH BLK

RED

BLK

BLU

HEATER 200 W/ 120 VAC

RUST INHIBITOR CAPSULE

NC C NO

PS1

1

2

SW# 2

PG1

LOW PRESS

HIGH PRESS

ALARM ENABLE SWITCH

SW# 1

WIRING DIAGRAM REGULATOR PANEL ASSEMBLY

REGULATOR PANEL

FLEX HOSE, 48" SST

HEATER 200W/120VAC

BREATHER FILTER

N2-2-SYSTEM

REGULATOR PANEL

N2-A ABB N2-REGULATOR REPLACEMENT PANEL

N2-P WAUKESHA N2-REGULATOR REPLACEMENT PANEL R

NOTES: 1. ALL WIRES SIZE 12 AWG, UNLESS OTHERWISE SPECIFIED; USE AS REQUIRED. 2. 15 RING TERMINALS REQUIRED; RING TERMINALS INCLUDED AND BAGGED SEPARATELY. 3. PULL VENT PLUG UP TO ALLOW FOR ALTITUDE EQUALIZATION. ONCE NITROGEN GAS CIRCULATES THROUGH THE SYSTEM, PUSH DOWN TO CLOSE VENT PLUG. 4. WHEN PANEL IS SOLD SEPARATELY, ORDER PART NUMBER 1030-1733K FOR CONNECTION COMPONENTS.

4X .313

8.50

21.69

23.18

10.00

SHEET 1 OF 2

NOTES: 1. ALL CONTACTS IN THE DIAGRAM ARE SHOWN WITH THE SYSTEM DE-ENERGIZED AT ATMOSPHERIC PRESSURE. SW# 1 CONTACT 1-2 : CLOSES AT 0.25 PSIG & ABOVE. CONTACT 1-3 : CLOSES AT A PRESSURE OF 0.25 PSIG OR BELOW, SENDING AN ALARM, IF MONITORED. SW# 2 CONTACT 6-4 : CLOSES AT 5.5 PSIG & BELOW. CONTACT 6-5 : CLOSES AT A PRESSURE OF 5.5 PSIG OR ABOVE, SENDING AN ALARM, IF MONITORED. SW# 3 CONTACT BLU-BLK : N.C., OPENS AT 200.0 PSIG CONTACT RED-BLK : N.O., CLOSES AT 200.0 PSIG

NO LO C NO HI TRANS. TANK ALARMS 1 2 3

NITROGEN STORAGE ALARM

TRANS. TANK STOR. TANK

L1 N 120 N G HEATER SUPPLY POWER (VAC)

(4-20mA)

(4-20mA)

NO C NC + - + -

6 7

9 10 11 12 13 14 15

8

4 5

GR

GR

BLK

RED

12

1 1 BLK BLK

5

SW# 2

4

6

2

RED

BLK

BLU

NO C NC

NC C NO

5.5 PSI

5.5 PSI

2

PS1

SW# 3

HIGH PRESS

2 1 3

ALARM ENABLE SWITCH

BLIZZARD 60W PTC HEATER

.25 PSI .25 PSI

NO C NC

LOW PRESS

PG1

SW# 1

WIRING DIAGRAM

SHEET 2 OF 2

NOTES: 1. ALL WIRES SIZE 12 AWG, UNLESS OTHERWISE SPECIFIED; USE AS REQUIRED. 2. 15 RING TERMINALS REQUIRED; RING TERMINALS INCLUDED AND BAGGED SEPARATELY. 3. PULL VENT PLUG UP TO ALLOW FOR ALTITUDE EQUALIZATION. ONCE NITROGEN GAS CIRCULATES THROUGH THE SYSTEM, PUSH DOWN TO CLOSE VENT PLUG. 4. REGULATOR SET TO CONTROL PRESSURE AT 0.5 PSI.

11.00 13.00

3X .375

18.00

16.00

5.50

SHEET 1 OF 2

NOTES: 1. ALL CONTACTS IN THE DIAGRAM ARE SHOWN WITH THE SYSTEM DE-ENERGIZED AT ATMOSPHERIC PRESSURE. SW# 1 CONTACT 1-2 : CLOSES AT 0.25 PSIG & ABOVE. CONTACT 1-3 : CLOSES AT A PRESSURE OF 0.25 PSIG OR BELOW, SENDING AN ALARM, IF MONITORED. SW# 2 CONTACT 6-4 : CLOSES AT 8.5 PSIG & BELOW. CONTACT 6-5 : CLOSES AT A PRESSURE OF 8.5 PSIG OR ABOVE, SENDING AN ALARM, IF MONITORED. SW# 3 CONTACT BLU-BLK : N.C., OPENS AT 200.0 PSIG CONTACT RED-BLK : N.O., CLOSES AT 200.0 PSIG

WHT

BLK

5 6 4 SW# 2

2

RED

NO C NC

8.5 PSI

8.5 PSI

NO LO C NO HI NO C NC + - + - L1 N 120 N G ALARMS ALARM (VAC) (4-20mA) (4-20mA)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

.25 PSI .25 PSI

TRANS. TANK

NO C NC

1

WHT

HIGH PRESS

3

SW# 1

LOW PRESS

PG1

NITROGEN.STORAGE

TRANS TANK STOR-TANK

RED

BLK

BLU

HEATER SUPPLY POWER

NC C NO

PSI

SW# 3

BLK BLK

2

1

CONNECTOR

WHT BLK NATURAL CONVECTION

2

1

60W PTC HEATER

ALARM ENABLE SWITCH

WIRING DIAGRAM

SHEET 2 OF 2