PTC2- 2nd GENERATION HEATER SYSTEMS

Animated publication

PTC2-SYSTEMS

PTC2 A, F SERIES

PTC2 E, G SERIES

PTC2 B, C, D, H-M SERIES

REVISIONS

WAUKESHA PTC 2nd Generation Heater Systems

LTR.

REVISION

DATE APPROVAL

B 1) REM MOUNT PLT, OPT 1 [ER ECR# 150921A

AM JP

9/21/15

P T C 2 - X X X

1) REDRAWN IN PRO/E DATA BASE, CHGED LEGEND A-G TO A-F SERIES CHGED LEGEND E-F TO E-G SERIES PER ECR# 150730B

B1

TL JP

11/9/15

NOTES: 1. "TEMPERATURE ACTIVATED" - PTC HEATERS ARE CONTROLLED BY AN INTEGRAL THERMOSTAT SET TO ACTIVATE AT 5°C ± 3°C. 2. HI-RECOVERY PTC HEATERS OPERATE AS A STANDARD 200W OR 300W PTC HEATER WITH THE HI-RECOVERY 400W MODE ACTIVATED BY AN INTEGRAL THERMOSTAT SET TO ACTIVATE AT 5°C ± 3°C.

B2 1) PRO-E FONT UPDATED PER ECR# 160805D C 1) REM OPTIO -XX0 PER ECRE# 170308A C1 1) PTC2-A WAS 60W PER ECR# 190911A

AM JP

8/9/16

HEATER TYPE

3/16/2017 AM JP

20 WATT ASSY NATURAL CONVECTION

9/11/2019 AM JP

E

OPTION ADD

VOLTAGE

0 1

110 - 120 VAC

30 WATT ASSY NATURAL CONVECTION

DIN RAIL MOUNT 1030-1342-001

2

F

USE PTC2-SYSTEMS CONFIGURATION FOR PART NUMBER DESIGNATION AND ENTER PART NUMBER IN THE QUOTE CART FIELD "Company Name/Config. Part No."

220 - 240 VAC

40 WATT ASSY NATURAL CONVECTION

G

* NOTE: UNITS A, E, F & G ARE DUAL RATED FOR 120 - 240 VAC (USE "0" FOR VOLTAGE SELECTION

65 WATT ASSY NATURAL CONVECTION

A

FOR MORE INFORMATION ON THE [ PTC2-SYSTEM ] OR TO DOWNLOAD A BROCHURE OFF OUR WEBSITE, PLEASE CLICK HERE.

200 WATT, W/ FAN FORCED CONVECTION

B

300 WATT, W/ FAN FORCED CONVECTION

C

400 WATT, W/ FAN FORCED CONVECTION

D

200 WATT, W/ FAN FORCED CONVECTION TEMPERATURE ACTIVATED 300 WATT, W/ FAN FORCED CONVECTION TEMPERATURE ACTIVATED 400 WATT, W/ FAN FORCED CONVECTION TEMPERATURE ACTIVATED

H

J

K

200/400 WATT, W/ FAN 200W & FAN CONTIN.

L

400 WATT, HI-RECOVERY TEMPERATURE ACTIVATED

300/400 WATT, W/ FAN 200W & FAN CONTIN.

PTC HEATER "E, G SERIES"

PTC HEATER "A, F SERIES"

PTC HEATER "B, C, D, H - M SERIES"

DIN RAIL MOUNT

M

300 WATT, HI-RECOVERY TEMPERATURE ACTIVATED

MOUNTING: DIN RAIL SIZE: 2.75" W X 2.75"D X 3.75" H WIRE LEAD: 12 FEET (INCLUDED)

MOUNTING: DIN RAIL SIZE: 1.39" W X 2.236"D X 6.21" L

MOUNTING: DIN RAIL SIZE: 1.39" W X 2.236"D X 3.84" L

500 450 400 350 300 250 200 150 100 50 0

80 70 60 50 40 30 20 10 0

65 WATT

WATTS

WATTS

200 WATT 300 WATT 400 WATT

30 WATT 40 WATT

20 WATT

-40 -30 -20 -10 0 10 20 30 40

-10 0 10 20 30 40 50 60 70 INLET TEMPERATURE (CENTIGRADE) FORCED CONVECTION PTC HEATERS B, C & D SERIES

INLET TEMPERATURE (CENTIGRADE) NATURAL CONVECTION PTC HEATERS A, E, F & G SERIES

INLET TEMP. FROM HOT TO COLD

500 450 400 350 300 250 200 150 100 50 0

500 450 400 350 300 250 200 150 100 50 0

INLET TEMP. FROM COLD TO HOT

400 WATT

300 WATT

WATTS

WATTS

200 WATT

300 - 400 WATT

200 - 400 WATT

-10 0 10 20 30 40 50 60 70

-10 0 10 20 30 40 50 60 70

INLET TEMPERATURE (CENTIGRADE) HI-RECOVERY DUAL WATTAGE, FORCED CONVECTION PTC HEATERS L & M SERIES

INLET TEMPERATURE (CENTIGRADE) TEMPERATURE ACTIVATED, FORCED CONVECTION PTC HEATERS H , J & K SERIES

PTC2-CONFIG SHEET 2 OF 2

HS1-SYSTEMS

HS1 "B & C" SERIES

REVISIONS

LTR

REVISION

DATE

APPROVAL

NOTE: 1. HI-RECOVERY HS1 HEATERS OPERATE AS A STANDARD 200 WATT HS1 HEATER WITH THE HI-RECOVERY 400 WATT MODE ACTIVATED BY AN INTEGRAL THERMOSTAT SET TO ENERGIZE AT 5°C ± 3°C (41°F ± 5°F) ALL FORCED AIR HEATERS ARE EQUIPPED WITH A HIGH TEMPERATURE HEATER SHUTOFF AT 40°C ± 3°C (104°F ± 5°F) (FAN REMAINS ON). THE HEATER RE-ACTIVATES AS THE TEMPERATURE FALLS.

1) NEW DRAWING PER DRC# 170615A

A

JP AM

6/16/2017

Heat Source Heater System ONE

1) REMOVE CONVECTION MODEL

PER ECR# 200929D B

JP AM

9/29/2020

H S 1 - X X X

HEATER TYPE

MOUNTING

VOLTAGE

0 1

2

DIN CLIP & DIN RAIL

110-120 VAC

200 WATT, W/FAN FORCED CONVECT.

B

220-240 VAC

200/400 WATT, W/FAN 200W (NORMAL) 400W (HI-RECOVERY)

C

HS1 HEATER SERIES "B & C"

4" DIN RAIL

MOUNTING: DIN RAIL SIZE: 4.15 W x 3.35 D x 3.91 L

150 200 250 300 350 400 450

100 125 150 175 200 225 250

FROM HOT TO COLD

WATTAGE OUTPUT

WATTAGE OUTPUT

FROM COLD TO HOT

0 50 100

0 50 75

-40 -30 -20 -10 0 10 20 30 40 50 INPUT AIR TEMPERATURE °C 200/400W FORCED AIR HS1 HEATER

-40 -30 -20 -10 0 10 20 30 40 50 INPUT AIR TEMPERATURE °C 200W FORCED AIR HS1 HEATER

Made with FlippingBook Annual report