MINI-INERT AIR SYSTEMS
Animated publication
MINI INERT AIR SYSTEMS
MN2-KITS
TBD TBD TBD TBD TBD TBD TBD TBD TBD
REVISIONS
LTR.
REVISION
DATE APPROVAL
MN2 - XXXXXX WAUKESHA N2 Systems
1) UPGRADE ENCLOSURE TO 12 GAUGE 2) LOCKABLE ENCLOSURE PER ECR# 240819A
H
8/19/2024 AM FF
NOTES: 1. 1/4" CABINET MOUNTNIG HARDWARE IS NOT SUPPLIED WITH THE UNIT. 2. NEMA 4X RATING PRIOR TO MODIFICATION FOR THE N2 SYSTEM COMPONENTS.
SYSTEM TYPE
MINIATURE N2 SYSTEM SEPARATE CYLINDER
CABINET TYPE
CABINET COLOR
ALARMS
HEATER
OPTIONS
TANK PRESSURE GAUGE
MATERIAL: 12 GA. HOT ROLLED PICKLED LATCH PAD LOCKABLE MATERIAL: 12 GA. 304 STAINLESS STEEL LATCH PAD LOCKABLE MATERIAL: FIBERGLASS 18"T X 16"W X 10"D LATCH PAD LOCKABLE
STD. ANSI 70 GREY (5 MIL)
0
0
A
0
0
0
NONE
NONE
NONE
NONE
FINAL REGULATION ONLY: FOR USE WITH LESS THAN 10 PSIG SUPPLY 24" S.S EXTERNAL CONN. PIGTAIL (FLEXIBLE) (CGA 555) MALE BOTTLE 24" S.S EXTERNAL CONN. PIGTAIL (FLEXIBLE) (CGA 580) FEMALE BOTTLE
0-15 PSIG STANDARD DRY GAUGE 0-15 PSIG LIQUID FILLED GAUGE
60W PTC CONVECTION HEATER
LOW BOTTLE PRESSURE TRANSDUCER
NO PAINT S.S. CABINET ONLY
1
1
B
1
1
1
2
2
2
PRESSURE VACUUM GAUGE W/LOW & HIGH PRESS. ALM
14.00 OVERALL
3
12.00 C/C MOUNTING HOLES
6.87 DEPTH
3
0-5 PSIG DRY GAUGE
4
LOW BOTTTLE ALARM OPTION 1
60W PTC HEATER OPTION 1
16.75 C/C MOUNTING HOLES
17.50
PRESSURE/ VACUUM GAUGE OPTION 3
USE MN2-SYSTEMS CONFIGURATION FOR PART NUMBER DESIGNATION AND ENTER PART NUMBER IN THE QUOTE CART FIELD "Company Name/Config. Part No."
FOR MORE INFORMATION ON THE [MN2-SYSTEMS] OR TO DOWNLOAD A BROCHURE OFF OUR WEBSITE, PLEASE CLICK HERE.
TERMINAL STRIP
SUPPLY
LOCKABLE LATCHES STANDARD
TO TANK
USE MN2-SYSTEMS CONFIGURATION FOR PART NUMBER DESIGNATION AND ENTER PART NUMBER IN THE QUOTE CART FIELD "Company Name/Config. Part No."
MN2-ENCLOSURE (SEE CONFIG. DWG. FOR OPTIONS)
FOR MORE INFORMATION ON THE [MN2-SYSTEMS] OR TO DOWNLOAD A BROCHURE OFF OUR WEBSITE, PLEASE CLICK HERE.
PANEL
PIGTAIL
EXPLODED VIEW
ISO VIEW
MN2-SYSTEM
Made with FlippingBook - Online catalogs